ROBUSTAIRE™ DIFFUSED AERATION
RobustAire™ Diffused Aeration
Kasco RobustAire™ Diffused Aeration systems add beneficial water mixing and movement from the bottom up to prevent weed overgrowth, algae, fish kills, and other issues. Using a shore-mounted compressor, air is pushed through self-weighted lines to a diffuser on the bottom of a pond, lake, or tank allowing water to be thoroughly mixed helping to prevent the most common water quality issues.
Newly designed Small Cabinets are now available in addition to our Medium and Large Cabinets, completing our offering of RobustAire systems with AireGuard Cabinet Technology. Utilizing this new approach to airflow, compressor cabinets are kept cooler and cleaner. Read more about the new Small Cabinets here.
Warranty periods:
- Diffuser: Lifetime
- Cabinet: Lifetime
- Tubing: 15 years
- Compressor Motor: 3 years
- Compressor Piston Cups & Cylinders: 2 years
About
Funktionen
No-Cabinet Packages
Post Mount Packages
NEW Small Cabinet Packages
Medium Cabinet Packages
Large Cabinet Packages
50HZ Units (International)
AireGuard Cabinet Technology
Kasco patented AireGuard Cabinet Technology tackles the biggest stressors on compressor operation: heat and dust. With this innovative design, air is immediately passed through an external filtration layer that removes excess dust and debris. Powerful fans then pull this clean air through the compressor, instead of across it, allowing the compressor to stay much cooler and operate at extreme efficiency. The dual-action filtering and air movement acts as a safeguard for the compressor motor and entire system, allowing RobustAire to provide a reliable source of mixing and movement to the water.
This technology is offered in Kasco Small (NEW), Medium and Large Cabinets. These cabinets feature a sleek new look, external maintenance indicators, easy-to-remove panels for scheduled maintenance, quiet operation, and a paint color that seamlessly blends with the environment.
Cabinet Options
- NEW Small Cabinet (1-3 diffusers)
- Medium Cabinets (4-6 diffusers)
- Large Cabinet (7-12 diffusers)
- Post Mount Cabinet (1-3 diffusers) – For installations where compressor cabinets can be mounted above the ground
- No-Cabinet (1-3 diffusers)
Common Applications
- Backyard ponds & lakes
- Industrie
- Mixing
- Winterkill prevention
- Waterfowl protection
AireGuard Cabinet Technology
Kasco patented AireGuard Cabinet Technology tackles the biggest stressors on compressor operation: heat and dust. With this innovative design, air is immediately passed through an external filtration layer that removes excess dust and debris. Powerful fans then pull this clean air through the compressor, instead of across it, allowing the compressor to stay much cooler and operate at extreme efficiency. The dual-action filtering and air movement acts as a safeguard for the compressor motor and entire system, allowing RobustAire to provide a reliable source of mixing and movement to the water.
This technology is offered in Kasco Small (NEW), Medium and Large Cabinets. These cabinets feature a sleek new look, external maintenance indicators, easy-to-remove panels for scheduled maintenance, quiet operation, and a paint color that seamlessly blends with the environment.
Cabinet Options
- NEW Small Cabinet (1-3 diffusers)
- Medium Cabinets (4-6 diffusers)
- Large Cabinet (7-12 diffusers)
- Post Mount Cabinet (1-3 diffusers) – For installations where compressor cabinets can be mounted above the ground
- No-Cabinet (1-3 diffusers)
Common Applications
- Backyard ponds & lakes
- Industrie
- Mixing
- Winterkill prevention
- Waterfowl protection
All RobustAire™ diffused aeration systems are available with an optional remote manifold allowing the compressor to be installed up to a mile away from the water’s edge.
Packages include:
- Diffuser assembly
- Compressor mounting option
- Compressor(s)
- Some models include tubing (see cut sheet for details)
System Features:
- Great for depths 8 ft. and deeper
- 34% quieter than previous models
- Large filters on compressors feature maintenance indicator alerting when cleaning is needed
- No electricity required in the water
- Speeds up organic decomposition
- Creates open water, preventing ice damage
- Designed for continuous operation
All RobustAire™ diffused aeration systems are available with an optional remote manifold allowing the compressor to be installed up to a mile away from the water’s edge.
Packages include:
- Diffuser assembly
- Compressor mounting option
- Compressor(s)
- Some models include tubing (see cut sheet for details)
System Features:
- Great for depths 8 ft. and deeper
- 34% quieter than previous models
- Large filters on compressors feature maintenance indicator alerting when cleaning is needed
- No electricity required in the water
- Speeds up organic decomposition
- Creates open water, preventing ice damage
- Designed for continuous operation
Product Notes:
- Remote manifold systems are available allowing installations long distances from power. Add “-RM” to the end of any part number above.
- System 2 (RA2-NC) is available with (1) 1/2HP compressor for more air flow. Add “-DP” to the end of any RA2-NC part number.
- No-Cabinet packages include tubing.
Teilenummer | Anzahl der Diffusoren | Spannung | Phase | Kompressor | Amps | Rolls of 3/8 in. Tubing (each roll is 100 ft.) |
---|---|---|---|---|---|---|
RA1-NC | 1 | 120 | 1 | KM-60C (1/4HP x 1) | 2.5 | 1 |
RAH1-NC | 1 | 208-240 | 1 | KM-60HC (1/4HP x 1) | 1.25 | 1 |
Ra2-NC | 2 | 120 | 1 | KM-60C (1/4HP x 1) | 2.5 | 2 |
RAH2-NC | 2 | 208-240 | 1 | KM-60HC (1/4HP x 1) | 1.25 | 2 |
RA3-NC | 3 | 120 | 1 | KM-120C (1/2HP x 1) | 3.5 | 3 |
RAH3-NC | 3 | 208-240 | 1 | KM-120HC (1/2HP x 1) | 1.75 | 3 |
Product Notes:
- Remote manifold systems are available allowing installations long distances from power. Add “-RM” to the end of any part number above.
- System 2 (RA2-NC) is available with (1) 1/2HP compressor for more air flow. Add “-DP” to the end of any RA2-NC part number.
- No-Cabinet packages include tubing.
Product Notes:
- Remote manifold systems are available allowing installations long distances from power. Add “-RM” to the end of any part number above.
- System 2 (RA2-PM) is available with (1) 1/2HP compressor for more air flow. Add “-DP” to the end of any RA2-PM part number.
- Post Mount packages include tubing.
Teilenummer | Anzahl der Diffusoren | Spannung | Phase | Kompressor | Amps | Rolls of 3/8 in. Tubing (each roll is 100 ft.) |
---|---|---|---|---|---|---|
RA1-PM | 1 | 120 | 1 | KM-60C (1/4HP x 1) | 2.5 | 1 |
RAH1-PM | 1 | 208-240 | 1 | KM-60HC (1/4HP x 1) | 1.25 | 1 |
Ra2-PM | 2 | 120 | 1 | KM-60C (1/4HP x 1) | 2.5 | 2 |
RAH2-PM | 2 | 208-240 | 1 | KM-60HC (1/4HP x 1) | 1.25 | 2 |
RA3-PM | 3 | 120 | 1 | KM-120C (1/2HP x 1) | 3.5 | 3 |
RAH3-PM | 3 | 208-240 | 1 | KM-120HC (1/2HP x 1) | 1.75 | 3 |
Product Notes:
- Remote manifold systems are available allowing installations long distances from power. Add “-RM” to the end of any part number above.
- System 2 (RA2-PM) is available with (1) 1/2HP compressor for more air flow. Add “-DP” to the end of any RA2-PM part number.
- Post Mount packages include tubing.
Product Notes:
- Remote manifold systems are available allowing installations long distances from power. Add “-RM” to the end of any part number above.
- System 2 (RA2) is available with (1) 1/2HP compressor for more air flow. Add “-DP” to the end of any RA2 part number.
- Small Cabinet systems can be mounted off the ground with available mounting bracket. Bracket sold separately.
- Small Cabinet systems include tubing.
Teilenummer | Anzahl der Diffusoren | Spannung | Phase | Kompressor | Amps | Rolls of 3/8 in. Tubing (each roll is 100 ft.) |
---|---|---|---|---|---|---|
RA1 | 1 | 120 | 1 | KM-60C (1/4HP x 1) | 2.5 | 1 |
RAH1 | 1 | 208-240 | 1 | KM-60HC (1/4HP x 1) | 1.25 | 1 |
Ra2 | 2 | 120 | 1 | KM-60C (1/4HP x 1) | 2.5 | 2 |
RAH2 | 2 | 208-240 | 1 | KM-60HC (1/4HP x 1) | 1.25 | 2 |
RA3 | 3 | 120 | 1 | KM-120C (1/2HP x 1) | 3.5 | 3 |
RAH3 | 3 | 208-240 | 1 | KM-120HC (1/2HP x 1) | 1.75 | 3 |
Product Notes:
- Remote manifold systems are available allowing installations long distances from power. Add “-RM” to the end of any part number above.
- System 2 (RA2) is available with (1) 1/2HP compressor for more air flow. Add “-DP” to the end of any RA2 part number.
- Small Cabinet systems can be mounted off the ground with available mounting bracket. Bracket sold separately.
- Small Cabinet systems include tubing.
Product Notes:
- Medium Cabinet Systems 4 – 6 do not include tubing. Tubing must be ordered separately.
- Remote manifold systems are available allowing installations long distances from power. Add “-RM” to the end of any part number above
Teilenummer | Anzahl der Diffusoren | Spannung | Phase | Kompressor | Amps |
---|---|---|---|---|---|
Ra4 | 4 | 120 | 1 | KM-120C (1/2HP x 2) | 7 |
RAH4 | 4 | 208-240 | 1 | KM-120HC (1/2HP x 2) | 3.5 |
Ra5 | 5 | 120 | 1 | KM-120C (1/2HP x 2) | 7 |
RAH5 | 5 | 208-240 | 1 | KM-120HC (1/2HP x 2) | 3.5 |
RA6 | 6 | 120 | 1 | KM-120C (1/2HP x 2) | 7 |
RAH6 | 6 | 208-240 | 1 | KM-120HC (1/2HP x 2) | 3.5 |
Product Notes:
- Medium Cabinet Systems 4 – 6 do not include tubing. Tubing must be ordered separately.
- Remote manifold systems are available allowing installations long distances from power. Add “-RM” to the end of any part number above
Product Notes:
- Large Cabinet Systems 7 – 12 do not include tubing. Tubing must be ordered separately.
- Remote manifold systems are available allowing installations long distances from power. Add “-RM” to the end of any part number above.
Teilenummer | Anzahl der Diffusoren | Spannung | Phase | Kompressor | Amps |
---|---|---|---|---|---|
RA7 | 7 | 120 | 1 | KM-120C (1/2HP, x3) | 10.5 |
RAH7 | 7 | 208-240 | 1 | KM-120HC (1/2HP, x3) | 5.25 |
RA8 | 8 | 120 | 1 | KM-120C (1/2HP, x3) | 10.5 |
RAH8 | 8 | 208-240 | 1 | KM-120HC (1/2HP, x3) | 5.25 |
RA9 | 9 | 120 | 1 | KM-120C (1/2HP, x3) | 10.5 |
RAH9 | 9 | 208-240 | 1 | KM-120HC (1/2HP, x3) | 5.25 |
RA10 | 10 | 120 | 1 | KM-120C (1/2HP, x4) | 14 |
RAH10 | 10 | 208-240 | 1 | KM-120HC (1/2HP, x4) | 7 |
RA11 | 11 | 120 | 1 | KM-120C (1/2HP, x4) | 14 |
RAH11 | 11 | 208-240 | 1 | KM-120HC (1/2HP, x4) | 7 |
RA12 | 12 | 120 | 1 | KM-120C (1/2HP, x4) | 14 |
RAH12 | 12 | 208-240 | 1 | KM-120HC (1/2HP, x4) | 7 |
Product Notes:
- Large Cabinet Systems 7 – 12 do not include tubing. Tubing must be ordered separately.
- Remote manifold systems are available allowing installations long distances from power. Add “-RM” to the end of any part number above.
Product Notes:
- RAE Systems do not include tubing. Tubing must be ordered separately.
- Remote manifold systems are available allowing installations long distances from power. Add “-RM” to the end of any part number above.
50HZ Models | Cabinet | Anzahl der Diffusoren | Spannung | Kompressor | Amps |
---|---|---|---|---|---|
RAE1-NC | No-Cabinet | 1 | 220 | KM-60HC (1/4HP x 1) | 1.25 |
RAE2-NC | No-Cabinet | 2 | 220 | KM-120HC (1/2HP x 1) | 1.75 |
RAE3-NC | No-Cabinet | 3 | 220 | KM-120HC (1/2HP x 1) | 1.75 |
RAE1-PM | Pfosten-Einfassung Kabinett | 1 | 220 | KM-60HC (1/4HP x 1) | 1.25 |
RAE2-PM | Pfosten-Einfassung Kabinett | 2 | 220 | KM-120HC (1/2HP x 1) | 1.75 |
RAE3-PM | Pfosten-Einfassung Kabinett | 3 | 220 | KM-120HC (1/2HP x 1) | 1.75 |
RAE1 | Small Cabinet | 1 | 220 | KM-60HC (1/4HP x 1) | 1.25 |
RAE2 | Small Cabinet | 2 | 220 | KM-120HC (1/2HP x 1) | 1.75 |
RAE3 | Small Cabinet | 3 | 220 | KM-120HC (1/2HP x 1) | 1.75 |
RAE4 | Medium Cabinet | 4 | 220 | KM-120HC (1/2HP x 2) | 3.5 |
RAE5 | Medium Cabinet | 5 | 220 | KM-120HC (1/2HP x 2) | 3.5 |
RAE6 | Medium Cabinet | 6 | 220 | KM-120HC (1/2HP x 2) | 3.5 |
RAE7 | Großer Schrank | 7 | 220 | KM-120HC (1/2HP x 3) | 5.25 |
RAE8 | Großer Schrank | 8 | 220 | KM-120HC (1/2HP x 3) | 5.25 |
RAE9 | Großer Schrank | 9 | 220 | KM-120HC (1/2HP x 3) | 5.25 |
RAE10 | Großer Schrank | 10 | 220 | KM-120HC (1/2HP x 4) | 7 |
RAE11 | Großer Schrank | 11 | 220 | KM-120HC (1/2HP x 4) | 7 |
RAE12 | Großer Schrank | 12 | 220 | KM-120HC (1/2HP x 4) | 7 |
Product Notes:
- RAE Systems do not include tubing. Tubing must be ordered separately.
- Remote manifold systems are available allowing installations long distances from power. Add “-RM” to the end of any part number above.
Links to product files including specifications,
owner’s manuals, and other related documents
for RobustAire™ Diffused Aeration.
- RobustAire Flyer
- RobustAire Small Cabinet Manual
- RobustAire Medium Cabinet Manual
- RobustAire Large Cabinet Manual
- RobustAire Owner's Manual (Base Mount, Post Mount, & No-Cabinet)
- RobustAire Diffuser Assembly
- Remote Manifold Installation Instructions (RA1-3 Systems)
- Remote Manifold Installation Instructions (RA4-12 Systems)
- 50Hz RobustAire Small Cabinet Manual
- 50Hz RobustAire Medium Cabinet Manual
- 50Hz RobustAire Large Cabinet Manual
- RobustAire Diffuser SureSink Tubing Instructions
- RobustAire Diffuser Testing Summary
- Prüfung für feine Blase Diffusoren
NEW Small RobustAire Cabinets
Vital Mixing for Your Water
Featured Product Testimonials
- Keith
- Sam
- Chris